DNS is the abbreviation of Computer Domain Name System (Domain Name System or Domain Name Service), which is composed of resolvers and domain name servers. The domain name server refers to a server that stores the domain names and corresponding IP addresses of all hosts in the network, and has the function of converting domain names into IP addresses.
The blue box indicates detected temperature is abnormal (lower than 34°c).
The green box means normal;
The red box means over temperature.
1. Check if to turn on human body temperature measurement;
2. Check if there is three-point calibration.
3. Check if there is a face square in the thermal image (the face detection area is beyond the thermal field);
4. Check if the face square color of visible image is blue. If it’s blue check if you have enabled ‘abnormal temperature display’
1. Reduce the range of ‘Face Pixel Min’ and ‘Face Pixel Max’. For example, if the target is too close to the camera. Then the temperature will be too high, then we can reduce the ‘Face Pixel Max’ to the point that the camera can not detect the face. Then there is no square on the face, so the camera will not detect the temperature of the target.
2. Black body issue. If there is no blackbody, the blackbody is not enabled or the blackbody is covered, the temperature fluctuation may be big.
Thermal mapping has been configured precisely.We can adjust one point in visible image to adjust the
Square position slightly;
1. check if the face is in the detection area.
2. check if the algorithm software version is displayed.
3. check if the face snapshot is turned on and if the schedule time is set.
4. check if target is standing two far away so the actual face pixel is smaller than the value of ‘Face Pixel Min’ in ‘Parameter Configure’.
5. Check the installation height of the camera and the height of the target, and ensure that the vertical angle between the camera and target's face is less than 30 degrees.
6. Check if the target's face angle is within the requirements of ‘Yaw Degree’, ‘Tilt Degree’ and ‘Pitch Degree’ in the WEB setting.
1.Saving configuration fails when clicking ‘Apply’.
Error code ‘Application failed’.
Solution: clear IE cache.
1. Open->Internet options->safety. Delete temporary files, historical records, etc.
2. Open the browser again, enter the device reconfiguration parameters, and click apply.
1.Login the camera web interface on IE, make sure the new plugin has correctly installed.
Note: close the browser while installing the plugin.
2.Parameter configuration
1)Enable face detection
2)Draw the area according to the real scenario, max. 8 areas supported, usually we use one detection area to cover where people could potentially appear in 3-5m.
3)For confidence coefficient, we suggest to keep the default value. It’ s for face matching level with the model built in algorithm.
4)For face pixel min and max, we suggest to keep the default value. Faces only in this range can be detected.
5)We have two snapshot mode.
Timing: ‘upload interval’ is associated with ‘timing’, camera will upload one picture every 5 seconds;
Optical: ‘snapshot count’ is associated with ‘optical’, camera will upload the best face picture in 5 seconds.
6)For other settings, we suggest to keep as default.
7)On ‘temperature parameters’ tag.
We need to enable the button first.
Select the unit depending on your habits.
[IMPORTANT] Set the mount distance according to the real installation, whose value should be the horizontal distance from the detection area to the camera.
For other settings, we suggest to keep as default.
Hit ‘apply’ to save the settings.
3.[IMPORTANT] Thermal mapping
This step is mainly for matching the thermal image with the visible image, which can ensure the measurement accuracy.
1)Adjust the zoom times and focus on the visible image.
2)There are eight groups of ID, and each group ID contains three points.
3)Pick out three points that you can clearly see in the thermal image, mark them with point1, point2 and point3.
4)Find the three locations of the three points in the visible image, and mark them with the same point numbers associated with those in thermal image.
Note: we suggest to choose three points that far away from each other, so the triangle of ABC can cover 70% of the image.
5)Hit ‘apply’ to save the settings.
6)Test if the rectangle can correctly surround the face, and perfect it by adjusting the three points.
4.Thermal calibration
1)Install the blackbody properly where the camera can see it. The blackbody needs to be powered on for at least 20 mins to reach to a stable temperature.
2)Enable the button.
3)If you turn on ‘display area info’, the blackbody will also be showed in a rectangle with temperature on thermal image.
4)Put the real installation distance and temperature that showing on the blackbody, 40 is the default value.
5)Keep the ‘emission rate’ as the default value.
6)Draw an area to cover the black body.
7)Hit ‘apply’ to save the settings.
Writer: Leo
Video
Video has 2 mode: (1) One-channel, (2) Multi-channel; Each video mode has 3 mount type: (1)Ceiling, (2)Table, (3)Wall; Under different video mode there are different fisheye type, different video mode switch to each other the device need to restore, switch mount type and fisheye type don’t need restore. After changing video mode the configuration related to video will reset to factory default setting, include motion alarm, tamper, OSD.
1.One-channel
In the One-channel mode the function same as before.
2.Multi-channel
Multi-channel video mode has 3 fisheye types:
(1)Fisheye+Panoramat+3*PTZ
Fisheye+Panorama+3*PTZ, in this fisheye type there are 5 channels, video recording just get stream 1(fisheye stream), all the 5 channels have 2 video encode types: H.264 and MJPEG; maximum frame rate is 15; in every channel can set own OSD; motion detect only can be set in the fisheye channel, but it is efficacious in other channels too; tamper is only can be set in the fisheye channel,it is efficacious in other channel too.
Channel 1 is Fisheye channel: resolution only one 1280*1280;
Channel 2 is 360°Panorama channel(in the Wall mount type the image is 180°Panorama):resolution support 2018*1536 and 1080P;
From channel 3 to 5(PTZ): resolution support 1024*768, D1, VGA.
(2)Fisheye(main)+Fisheye(sub)+3*PTZ
Fisheye(main)+Fisheye(sub)+3*PTZ, in this fisheye type there are 4 channels, video recording just get stream 1(fisheye stream), all the 4 channels have 2 video encode types: H.264 and MJPEG; maximum frame rate is 15; in every channel can set own OSD;motion detect only can be set in the fisheye channel, but it is efficacious in other channels too; tamper is only can be set in the fisheye channel, it is efficacious in other channel too.
Channel 1 is Fisheye channel: in this channel there are 2 streams, stream 1 support 2 kind resolution:2048X2048, 1280X1280; stream 2 only one 720X720;
From channel 2 to 4(PTZ): support 3 kinds resolution 1024X768、D1、VGA.
(3)Fishieye +4*PTZ
Fishieye+4*PTZ, in this fisheye type there are 4 channels, video recording just get stream 1(fisheye stream), all the 5 channels have 2 video encode types: H.264 and MJPEG; maximum frame rate is 15; in every channel can set own OSD;motion detect only can be set in the fisheye channel, but it is efficacious in other channels too; tamper is only can be set in the fisheye channel, it is efficacious in other channel too.
Channel 1 is Fisheye channel: resolution is 1280X1280;
From channel 2 to channel 5 (PTZ): support 3 kinds resolution 1024X768、D1、VGA.
CGI Alarm Service Center config page introduction
The CGI alarm messages pushed by the device are assembled in the format following the IP addresses of the start and end URL. The assembled string is sent to the CGI alarm server through the HTTP protocol.
(1) URL Start: Indicate that send URL at the alarm starting point, the format is as follows:
(A)The format of the reporting information URL for license plate recognition is defined as follows:
(B)The format of the reporting common alarm information is defined as follows:
The 192.168.35.74 is target IP address (Alarm server IP address),80 is the corresponding port。
(2) URL End: Indicate that send URL at the alarm ending point, the format is same as URL Start. URL Start can be same as URL End.
(3) Username: username of IPC; Password: password of IPC.
(4) The proxy server is a CGI alarm forwarding server that implements alarm forwarding, among which the address is forwarding IP (for example:192.168.35.74), the port is forwarding port (for example: 80)
(5) The platform User Name: username of the forwarding server (for example:1234565);
The platform password: password of the forwarding server(for example: 123456).
(6) Test the connection to the specified HTTP server: It used to test whether the network between IPC and proxy server is unobstructed. When the test button is clicked, if the network between IPC and is unobstructed, display test result is successful, otherwise display test fails.
(7) After completing filling in the above information, you need to click the “Apply” button to save the data.
(8) Status is ON
(9) Status is ON
(10)Above item (1), (2), (3), (4), (5) can’t be empty.
License plate must be readable and well lit
License plate dimensions must be at least :
* 150 pix for rectangular plates and 100 pix for two row plates (for Russia, Kazakhstan,Armenia, Uzbekistan, Serbia).
* 130 px for rectangular plates and 70 pix for two row plates (for all other supported countries).
Allowed tilt 5 degrees (clock and counterclockwise).
Vertical angle and Horizontal angle: should not exceed 30 degrees:
Example of good license plate at day and night